Potentiometer - comparing emf and finding internal resistance is a topic in Current Electricity, a Class 12 Physics chapter of the NEET-UG and JEE Main syllabus. TestBudy holds 22 published NEET-UG and JEE Main questions on Potentiometer - comparing emf and finding internal resistance, each with the marking scheme of the real paper.
- questions
- 22
- shown here
- 10
Five free tests with an account. Your score comes with the result; where you stand is Pro.
Potentiometer - comparing emf and finding internal resistance MCQs with solutions
10 of the 22 published questions on this topic, exactly as they appear in a test. Answers and worked solutions come with your result rather than on this page.
A potentiometer measures potential difference accurately by using a
- A. null method
- B. high-current deflection method
- C. thermal method
- D. magnetic resonance method
In an experiment to find emf of a cell using potentiometer, the length of null point for a cell of emf is found to be . If this cell is replaced by another cell of emf E, the length-of null point increases by . The value of is . The value of is ____________.
In a potentiometer arrangement, a cell of emf 1.20 V gives a balance point at 36 cm length of wire. This cell is now replaced by another cell of emf 1.80 V. The difference in balancing length of potentiometer wire in above conditions will be ___________ cm.
In a potentiometer arrangement, a cell gives a balancing point at 75 cm length of wire. This cell is now replaced by another cell of unknown emf. If the ratio of the emf's of two cells respectively is 3 : 2, the difference in the balancing length of the potentiometer wire in above two cases will be ___________ cm.
In the given circuit of potentiometer, the potential difference E across AB (10 m length) is larger than E 1 and E 2 as well. For key K 1 (closed), the jockey is adjusted to touch the wire at point J 1 so that there is no deflection in the galvanometer. Now the first battery (E 1 ) is replaced by second battery (E 2 ) for working by making K 1 open and K 2 closed. The galvanometer gives then null deflection at J 2 . The value of is , where a = _________.
With the help of potentiometer, we can determine the value of emf of a given cell. The sensitivity of the potentiometer is (A) directly proportional to the length of the potentiometer wire (B) directly proportional to the potential gradient of the wire (C) inversely proportional to the potential gradient of the wire (D) inversely proportional to the length of the potentiometer wire Choose the correct option for the above statements :
- A. A only
- B. B and D only
- C. A and C only
- D. inversely C only
A null point is found at 200 cm in potentiometer when cell in secondary circuit is shunted by 5. When a resistance of 15 is used for shunting, null point moves to 300 cm. The internal resistance of the cell is ___________.
A potentiometer wire of length is connected in series with a resistance 780 and a standard cell of emf . A constant current flows through potentiometer wire. The length of the null point for cell of emf is found to be . The resistance of the potentiometer wire is ____________ .
A cell, shunted by a 8 resistance, is balanced across a potentiometer wire of length 3 m. The balancing length is 2 m when the cell is shunted by 4 resistance. The value of internal resistance of the cell will be ____________ .
A potentiometer wire of length 10 m and resistance 20 is connected in series with a 25 V battery and an external resistance 30 . A cell of emf E in secondary circuit is balanced by 250 cm long potentiometer wire. The value of E (in volt) is . The value of x is __________.
Common mistakes in Potentiometer - comparing emf and finding internal resistance
Recorded against questions in this topic that are not shown above, so none of these points at an answer you can see on this page.
- Uses the inverse ratio of balancing lengths.
- Uses the total balancing length instead of the decrease relative to loaded length.
- Assumes accuracy comes from zero instrument resistance rather than zero test current.
- Treats the loaded terminal voltage as larger than the open-circuit emf.